Atomic MB-50 Dokumentacja

Przeglądaj online lub pobierz Dokumentacja dla Wzmacniacze audio Atomic MB-50. Atomic MB-50 Specifications Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 152
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 2 - ATOM FULL LCD

10INTRODUCTIONWelcome to OCEANIC and thank you for choosing the ATOM !It is extremely important that you read this Operating Manual in sequence and un

Strona 3

100No Deco Secondary Display information includes (Fig. 88) -> Day of the Week graphic (MON, TUE, etc.)> Temperature with icon and graphic F (or

Strona 4

101No Deco Safety Stop Main DisplayInformation includes (Fig. 89) -> Tissue Loading Bar Graph> Transmitter Link icon> Graphic STOP> Stop D

Strona 5

102Upon entering Decompression Mode, the Audible Alarm willsound and the red LED Warning Light will flash for 10 seconds(unless set OFF), or until ac

Strona 6

103The amount of decompression Credit Time that you receive isdependent on Depth, with slightly less Credit given the deeperyou are below the Stop Dep

Strona 7

104Deco Alternate Display #1 information includes (Fig. 93) -• If the Reciver is set OFF, this display will be bypassed.> Tissue Loading Bar Graph

Strona 8 - FCC ID: MH8A

105Deco Secondary Display information includes (Fig. 95) -> Day of the Week graphic (MON, TUE, etc.)> Temperature with icon and graphic F (or C)

Strona 9

106Unless set OFF, the Audible Alarm will sound and the red LEDWarning Light will flash for 10 seconds, or until acknowledgedby pressing the S button.

Strona 10 - INTRODUCTION

107Delayed Violation Mode #1 (Fig. 97)If you remain above the Required Ceiling Stop Depth for morethan 5 minutes, the full Tissue Loading Bar Graph an

Strona 11 - Fig. 1 - Main Time

108Delayed Violation Mode #3 (Fig. 99)If you descend deeper than the Maximum Operating Depth of330 feet (99.9 meters), the accumulated Tissue Loading

Strona 12 - Fig. 2 - PC Interface

109Violation Gauge Mode has a Main (Default) screen (Fig. 100)that displays -> Full Bar Graph, flashing> Transmitter Link icon> Message UP &g

Strona 13 - FEATURES AND DISPLAYS

11OPERATING MODE STRUCTUREUnless it is operating in Dive Computer mode, the ATOM will beOn in the default MAIN TIME (home time) mode (Fig. 1), like as

Strona 14 - Fig. 3 - Sample Messages

110The countdown timer that appears when you try to access Time toFly does not represent Time to Fly. It is only provided to informyou of the time re

Strona 15

111If PO2 continues to increase, the value displayed will increasetoward a maximum value of 5.00 ATA in increments of .01 ATA.High PO2 Alarm (Fig. 103

Strona 16

112If the theoretical amount of oxygen accumulated equals, orexceeds, the limit for a single exposure, or the exposure limit fora 24 hour period (300

Strona 17 - Fig. 4 - Low Battery

113USER SET DIGITAL GAUGE MODEWhen Digital Gauge Mode is set for ON, the ATOM will operateas a Digital Depth Gauge/Timer without performing nitrogen a

Strona 18 - Status (Low)

114SUMMARY OF WARNING AND ALARM MESSAGESMESSAGE MEANINGVIEW > AIR Air Time Remaining is less than No Deco and O2 times.DECO > STOP > xxFT (M)

Strona 19 - WATCH FEATURES

115SWITCHING GAS MIXESWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,D

Strona 20 - (24 Hour Format)

116SWITCHING GAS MIXESDuring No Decompression and/or Decompression dives, theATOM can be manually switched from GAS 1 to GAS 2 to GAS3, changing Press

Strona 21 - Fig. 10 - Set Hour Format

117NOTE: If a switch to a new Gas Mix wouldexpose the diver to a prohibitive PO2 level of1.60 ATA or greater, the Audible Alarm willsound, the red LE

Strona 22 - Fig. 12 - Set Minute

118GAS 1 SWITCH PREVIEW DISPLAYInformation includes (Fig. 108) -> Transmitter Link icon (if the Transmitter is active)> Bar Graph, representing

Strona 23 - Fig. 14 - Set Month

119NOTE: When a switch is made to another GAS/TMT, there may be a delay of 5 to 15 secondsbefore the Receiver picks up the TMT's signal.SWITCHIN

Strona 24 - Fig. 15 - Set Day

12PC INTERFACEInterface with a PC is accomplished by connecting the ATOM(Watch) to a PC USB port using the USB Interface Cable pro-vided. The same C

Strona 25

120GAS 3 SWITCH PREVIEW DISPLAYInformation includes (Fig. 112) -> Transmitter Link icon (if the Transmitter is active)> Bar Graph, representing

Strona 26 - Fig. 17 - Set Alternate Time

121POST DIVE MODESWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc.

Strona 27 - Fig. 18 - Countdown Timer

122POST DIVE SURFACE MODEWhen you ascend to 4 feet (1.2 meters) or less, the ATOM willenter Surface Mode and begin counting your Surface Interval.TRAN

Strona 28 - Fig. 19 - Set Timer

123To view that dive's Log during the Transition Period -• Press and release the A button (< 2 seconds) to access thePreview screen (Fig. 115

Strona 29 - Fig. 21 - Chronograph

124To access Plan Mode (refer to page 77) -• Press the A button 1 time (while in Surface Mode).The Planning Sequence now displays adjusted No Decompr

Strona 30 - Fig. 23 - Daily Alarm

125UPLOADING SETTINGS AND DOWNLOADING DATAThe ATOM is configured with a Data Port located on the back of the left side that enables itto be connected

Strona 31 - Fig. 24 - Set Daily Alarm

126PC compatibility requirements:• IBM®, or compatible, Personal Computer with USB Port• Intel® Pentium 200 MHz or better microprocessor• Microsoft

Strona 32

127REFERENCEWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc. No. 12

Strona 33 - DIVE COMPUTER

128CARE AND CLEANINGProtect your ATOM from shock, excessive temperatures,exposure to chemicals, and tampering. Protect the lens againstscratches wit

Strona 34 - Fig. 25 - Nitrogen Bar Graph

129Oceanic recommends that you continue to have an inspection performed every year toensure it is working properly. The costs of annual inspections a

Strona 35 - Fig. 27 - Max O2 Exceeded

13GENERALFEATURES AND DISPLAYSWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference

Strona 36 - Fig. 28 - Tank Pressure

130BATTERY REPLACEMENTNOTE: The procedures that follow must be closely adhered to. Dam-age due to improper Battery replacement is not covered by the

Strona 37 - Fig. 30 - Safety Stop

131CAUTION: Damage due to improper Batteryreplacement is not covered by the product'slimited 2 year warranty.ATOM (Watch) Battery Removal• Loca

Strona 38

132Transmitter Battery RemovalLocate the Battery Hatch on the End of the Housing:• Apply a coin to the recessed slot of the Hatch (Fig. 120) andturn

Strona 39 - SURFACE SEQUENCE AND MODES

133Inspection (continued) -• Closely examine the sealing surfaces of the Battery Hatch(es)and Housing(s) for any signs of damage that might preventpr

Strona 40 - (Post Dive)

134ATOM (Watch) Battery Installation• Slide a new 3 volt type CR2430 Lithium Battery, negative (-)side down into the Battery Cavity. Slide it in fro

Strona 41

135Transmitter Battery Installation• Lightly lubricate the new Battery Cap O-ring with siliconegrease and install it onto the Battery Cap. DO NOT ro

Strona 42 - Fig. 36 - Surface Mode (O2)

136ATOM System Testing• Observe the LCD display to ensure it is consistently clear and sharp in contrast through-out the screen.• Set the Date Time,

Strona 43 - Fig. 38 - TMT3 Not Available

137TRANSMITTER INSTALLATION on REGULATORTo install the Transmitter on the Regulator First Stage:• Remove the existing Pressure Gauge and High Pressure

Strona 44 - (Watch Time Mode)

138ALTITUDE SENSING AND ADJUSTMENTPrior to the first dive of a series of repetitive dives, ALTITUDE (i.e., Ambient Pressure) ismeasured upon activatio

Strona 45

139NOTE: When the Conservative Factor feature is set ON, allowable dive times arecalculated based upon the next higher 3,000 foot (915 meter) Altitud

Strona 46

14SYMBOLS AND ALPHA NUMERIC GRAPHICSThe upper line of digits on the LCD screen is used to conveyalpha Messages such as Day of the Week, Operating Mode

Strona 47

140METRIC NO DECOMPRESSION LIMITS (HOURS:MINUTES) AT ALTITUDEAltitude 0` 611` 916` 1221` 1526` 1831` 2136` 2441` 2746` 3051`

Strona 48 - Fig. 42 - Set FO2 GAS1

141SPECIFICATIONSWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc. N

Strona 49 - (50% setting)

142CAN BE USED AS Watch Dive Computer (Air or Nitrox) Digital Depth Gauge/Timer With or without up to 3 TransmittersNO DECOMPRESSION MODELBasis:

Strona 50 - (100% setting)

143DIVE COMPUTER SURFACE MODES (continued) - Set D Group (Dive Data): Factory Settings:> FO2 GAS1 (Air, 21 to 50%) > Air> FO2 GAS2 (Air, 2

Strona 51 - Fig. 48 - Set FO2 Default

144DIVE MODESNo Decompression Dive: Main - Current Depth, Dive Time Remaining, Max Depth, Elapsed Dive Time, TLBG Alternate #1 - Tank Identifier, Ai

Strona 52 - Fig. 49 - Set Receiver

145SPECIFICATIONS (CONTINUED)DISPLAY RANGE/RESOLUTIONNumeric Displays: Range: Resolution: Dive Number 0 to 24 1 Depth 0 to 330 ft (100 m) 1 ft (.1 m

Strona 53 - Fig. 50 - Set Digital Gauge

146BAR GRAPHTissue Loading Bar Graph: segments Oxygen (O2) Bar Graph: segments No Decompression zone 1 to 4  Normal zone 1 to 4 Decompression zone

Strona 54 - Fig. 51 - Set A

147OPERATIONAL PERFORMANCE (continued)Power: ATOM (Watch) Battery 1 - 3 vdc, CR2430, Lithium battery Transmitter Battery 1 - 3 vdc, CR2, .75 Ahr,

Strona 55 - Fig. 52 - Set Audible Alarm

148PO2 (ATA) 0.60 0.70 0.80 0.90 1.00 1.10 1.20 1.30 1.40 1.50 1.60Maximum Duration forSingle Exposure (Min) (Hr)

Strona 56 - Fig. 53 - Set Depth Alarm

149RECORDSWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc. No. 12-2

Strona 57 - Fig. 54 - Set EDT Alarm

15Situations that will sound the Alarm include -• Watch Daily Alarm reaches time set (disabled during Dive Modes).• Watch Countdown Timer reaches 0:

Strona 58 - Fig. 55 - Set TLBG Alarm

150INSPECTION / SERVICE RECORDATOM Serial Number: _________________________________Transmitter #1 Serial Number: _________________________________Tran

Strona 59 - Fig. 56 - Set DTR Alarm

151OCEANIC WORLD WIDEOCEANIC USA2002 Davis StreetSan Leandro, CA 94577Tel: 510/562-0500Fax: 510/569-5404Web site: http://www.OceanicWorldWide.comO

Strona 61 - Fig. 58 - Set End Pressure

16A single short beep (which cannot be disabled) is emitted for the following -• Upon completion of a Hot Swap battery change.• Change from Delayed

Strona 62 - Fig. 59 - Set PO2 Alarm

17POWER SUPPLYThe ATOM (Watch) utilizes 1 - 3 volt CR2430 Lithium Battery.Transmitters use 1 - 3 volt, CR2 Lithium Battery. When used as aDive Comput

Strona 63 - Fig. 60 - Set U

18To check the condition of the ATOM or a Transmitter's Battery,depress the S button for 2 seconds while in Dive ComputerSurface Mode then releas

Strona 64 - Fig. 61 - Set Wet Activation

19WATCH FEATURESLOCAL DEFAULT TIMEThe normal screen sequence accessed with the M button is - Main Time > Alternate Time > Countdown Timer &g

Strona 65 - Fig. 62 - Set Units

2ATOM FULL LCDComponents:a. Mode (M) Buttonb. Select (S) Buttonc. Light (L) Buttond. Advance (A) Buttone. LED Warning Lightf. Bar Graphg. Icon - O2BGh

Strona 66 - Fig. 63 - Set Safety Stop

20MAIN TIMEInformation includes:> Alarm icon - if the Daily Alarm is set On (Fig. 9a)> Day of the Week graphic MON (or TUE, WED, THU, FRI,SAT,

Strona 67 - Fig. 64 - Set Conservative

21NOTE: MAIN TIME must be selected as the LocalDefault Time in order to set the Time and Date.Sequence of Time/Date settings:Hour Format screen >

Strona 68 - Duration

22• HINT - Pressing the A button repeatedly (< 2 seconds eachtime) will step through the Time/Date Settings, bypassingthose that don't requir

Strona 69 - Fig. 66 - Set Sampling Rate

23Displayed on the SET DATE screen will be the graphic YEAR,Month and Day (or Day and Month if set for metric), and theYEAR set point flashing.Set Yea

Strona 70 - Fig. 67 - Set TID1

24Set Day (Fig. 15)• Depressing and holding the S button while the DAY Set Pointis flashing will scroll through the Set Points in one-day (01)increme

Strona 71

25ALTERNATE TIME information includes:> Alarm icon - if the Daily Alarm is set On.> Lazy 8 symbol and Day of the Week graphic MON (or TUE,WED,

Strona 72 - Fig. 68 - Set TID2

26Once the Differential is selected and saved, Alternate Time/Datevalues will be based upon the MAIN TIME Set Points.Set ALTERNATE TIME information in

Strona 73

27Once set ON, a Countdown will run in the background until itcounts down to 0:00, or it is set OFF, or a Dive is made at whichtime it will default to

Strona 74 - Fig. 69 - Set TID3

28SET COUNTDOWN TIMERInformation includes (Fig. 19):> Graphics TIMR and SEt.> TIME symbol and HOUR Set Point (hr:) flashing.• Depressing and

Strona 75

29CHRONOGRAPH (Stop Watch/Lap Timer) (Fig. 21)• Pressing and releasing the M button momentarily 3 times (< 2seconds each) while the MAIN TIME scre

Strona 76 - (of the Watch)

3CONTENTSFULL DISPLAY ...

Strona 77

30• Depressing and holding the A button for 2 seconds will stopthe Timer and reset the Time to 0:00:00.00 (flashing).• Pressing and releasing the M

Strona 78

31• Upon being toggled to ON, the Alarm will be set to soundevery day at the Time indicated.• Depressing both the A and S buttons simultaneously for

Strona 79 - Fig. 71 - Plan Mode

32• Pressing and releasing the A button momentarily (< 2 sec-onds) will save the HOUR Set Point and/or advance to SETMINUTE with the Set Point fla

Strona 80 - Fig. 72 - Fly Mode

33DIVE COMPUTERFEATURES AND DISPLAYSWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Refe

Strona 81 - Fig. 73 - SAT Mode

34BAR GRAPHThe Bar Graph is used as a visual representation of nitrogenloading, or when accessed, oxygen accumulation. By default theBar Graph (Fig.

Strona 82

35Displays associated with oxygen and the O2 Bar Graph willappear if FO2 for any Gas has been set at a value other than'Air' (e.g., a numeri

Strona 83 - Fig. 74 - Log Preview

36While you cannot provide a guarantee against the occurrence ofdecompression sickness, you may choose your own personalzone of caution based upon age

Strona 84 - Fig. 76 - Log Oxygen

37During a No Decompression Safety Stop, the set Stop Depth(Fig. 30a) is displayed and during a Decompression condition,the required Ceiling Stop Dept

Strona 85 - Fig. 77 - History

38Temperature DisplayAmbient Temperature is displayed in Surface Mode (Fig.32Aa) and in Log Mode, and can be viewed on a SecondaryDisplay when accesse

Strona 86

39DIVE COMPUTERSURFACE SEQUENCE AND MODESWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and

Strona 87 - INFORMATION

4CONTENTS (continued)DIVE COMPUTER FEATURES AND DISPLAYS ...

Strona 88

40DIVE COMPUTER (DC) SURFACE MODEPressing and releasing the M button momentarily 5 times (< 2seconds each time) while the Watch Local Default Time

Strona 89 - Underwater

41During the first 10 minutes after a dive, DC SURFACE MODEremains on display as the DEFAULT screen. Main Time can beviewed for 3 seconds during tha

Strona 90

42Fig. 36 - Surface Mode (O2)SURFACE MODE - Button Operations:> Upper/Left - Mode (M) button> Upper/Right - Select (S) button> Lower/Right

Strona 91 - Fig. 80 - Nitrogen Bar Graph

43Fig. 37 - ATOM Battery GoodFig. 38 - TMT3 Not AvailableSYSTEM STATUS• Depressing and holding the S button for 2 seconds while inSurface Mode will a

Strona 92 - Fig. 82 - O2 Time Remaining

44Fig. 39 - Wet(DC Surface Mode)Fig. 40 - Wet(Watch Time Mode)WET CONTACTSThe Wet Contact Dive Mode Activation feature is active any timeWET ACTIVATIO

Strona 93 - Fig. 82 - ATR Alarm

45DIVE COMPUTER SET MODESSet Mode Sequence:Surface Mode > SET D > SET A > SET U > SERIAL No. screen.Access is gained by simultaneous 2 sec

Strona 94 - Fig. 83 - Ascent Rate

46Setting FO2 for Nitrox Dives:For each value of FO2, the Maximum Operating Depth (MOD) that can be achieved witheither the default maximum PO2 value

Strona 95 - Fig. 84 - Ascent Rate Alarm

47Maximum Operating Depths affected by the PO2 limit set will not be displayed when FO2for GAS 1 is set to AIR.Internally, the ATOM keeps track of the

Strona 96

48Fig. 42 - Set FO2 GAS1(Air setting)Fig. 43 - Set FO2 GAS1(32% setting)SET FO2 GAS 1 information includes (Fig. 42/43):> Graphic GAS1> Max De

Strona 97 - DIVE MODES

49SET FO2 GAS 2 information includes (Fig. 44/45):> Graphic GAS2> Max Depth allowed for the PO2 Alarm Set (if 21 to 100%)> FO2 value, flas

Strona 98

5CONTENTS (continued)SET U GROUP (UTILITIES) ...

Strona 99 - Fig. 86 - No Deco Alt #1

50SET FO2 GAS 3 information includes (Fig. 46/47):> Graphic GAS3> Max Depth allowed for the PO2 Alarm Set (if 21 to 100%)> FO2 value, flas

Strona 100 - Fig. 88 - No Deco Secondary

51SET FO2 50% DEFAULT information includes (Fig. 48):> Graphics DFLT and 50> Set Point graphic ON (or OFF), flashing.> Symbols FO2 and NIT

Strona 101 - Stop Main

52SET ATOM's RECEIVER information includes (Fig. 49):> Graphic RCVR> Set Point graphic ON (or OFF), flashing.• Pressing and releasing th

Strona 102 - Fig. 91 - Managing a Stop

53SET DIGITAL GAUGE DIVE information includes (Fig. 50):> Graphic GAUG> Set Point graphic ON (or OFF), flashing.• Pressing and releasing the

Strona 103 - Fig. 92 - Deco Main

54SET A GROUP (ALARMS)Set A Sequence:SET A > Audible > Depth > EDT > TLBG > DTR > Turn Pressure >End Pressure > PO2HINT: The

Strona 104 - Fig. 94 - Deco Alt #2

55SET AUDIBLE ALARM information includes (Fig. 52):> Graphic AUD> Set Point graphic ON (or OFF), flashing.• Pressing and releasing the S butt

Strona 105 - Violation

56SET DEPTH ALARM information includes (Fig. 53):> Graphic DPTH> Symbols MAX and FT (or M)> Set Point graphic value, flashing.• Pressing

Strona 106 - Responsible

57SET ELAPSED DIVE TIME (EDT) ALARMInformation includes (Fig. 54):> Graphic EDT> Symbols DIVE and TIME.> Set Point value, flashing.• Pres

Strona 107 - Violation #1

58SET TISSUE LOADING BAR GRAPH (TLBG) ALARMInformation includes (Fig. 55):> Graphic TLBG> TLBG Set Point (segments), flashing.• Pressing and

Strona 108 - Violation #3

59SET DIVE TIME REMAINING (DTR) ALARMInformation includes (Fig. 56):> Graphic DTR> Symbols TIME, NDC, O2, and AIR.> Set Point value, flash

Strona 109 - Mode (on Surface)

6CONTENTS (continued)DECOMPRESSION DIVE MODE ...

Strona 110 - Fig. 102 - High PO2 Warning

60SET TURN PRESSURE ALARM (for Transmitter 1 only)Information includes (Fig. 57A/B):> Graphic TURN> Set Point OFF or a numeric value, flashing

Strona 111 - Fig. 103 - High PO2 Alarm

61SET END PRESSURE ALARM information includes (Fig. 58):> Graphic END> Set Point numeric value, flashing.> Symbol PSI (or M)• Pressing an

Strona 112 - Fig. 104 - High O2 Alarm

62SET PO2 ALARM information includes (Fig. 59):> Graphic PO2> Set Point value, flashing.> Symbol MAX• Pressing and releasing the S button

Strona 113 - Fig. 105 - Digital Gauge Main

63SET U GROUP (UTILITIES)Set U Sequence:SET U > Wet Activation > Units > Safety Stop > ConservativeFactor > Backlight Duration > Sam

Strona 114

64SET WET ACTIVATION ON/OFFInformation includes (Fig. 61):> Graphic WET> Set Point graphic ON (or OFF) flashing.• Pressing and releasing the

Strona 115 - SWITCHING GAS MIXES

65SET UNITS information includes (Fig. 62):> Graphic UNIT> Set Point symbols/graphics F, FT, and PSI (or C, M, andBAR), flashing.• Pressing a

Strona 116 - Fig. 106 - Switch Gas Alert

66SET SAFETY STOP information includes (Fig. 63):> Graphic SAFE> Safety Stop Time Set Point, flashing.> Symbols STOP and TIME.> Safety

Strona 117

67SET CONSERVATIVE FACTOR information includes (Fig. 64):> Graphic CONS> Set Point ON (or OFF), flashing.> Symbols TIME and NDC.• Pressin

Strona 118 - Fig. 109 - GAS 2 Switch

68SET BACKLIGHT DURATION information includes (Fig. 65):> Graphic GLOW> Symbol TIME.> Set Point, flashing.• Pressing and releasing the S

Strona 119 - Back to GAS 1 was made

69SET SAMPLING RATE information includes (Fig. 66):> Graphic SAMP> Symbol TIME (or FT/M).> Set Point, flashing.• Pressing and releasing t

Strona 120 - Fig. 113 - Switch from GAS 2

7LIMITED TWO-YEAR WARRANTYFor details, refer to the Product Warranty Registration Card provided. Register on-line at www.OceanicWorldWide.comCOPYRIGH

Strona 121 - POST DIVE MODES

70SET TRANSMITTER 1 LINK CODE information includes (Fig. 67):> Graphics TID1, and ON (or OFF) flashing.> Set Point (numerical Link Code/transm

Strona 122 - Fig. 114 - Transition Period

71• Pressing and releasing the S button momentarily and repeatedly (< 2 seconds eachtime) will increase the Third Digit from 0 to 9 in increments

Strona 123 - (after Transition Period)

72SET TRANSMITTER 2 LINK CODE information includes (Fig. 68):> Graphics TID2, and ON (or OFF) flashing.> Set Point (Link Code/transmitter&apos

Strona 124

73• Pressing and releasing the S button momentarily and repeatedly (< 2 seconds eachtime) will increase the Third Digit from 0 to 9 in increments

Strona 125

74SET TRANSMITTER 3 LINK CODE information includes (Fig. 69):> Graphics TID3, and ON (or OFF) flashing.> Set Point (Link Code/transmitter&apos

Strona 126

75• Pressing and releasing the S button momentarily and repeatedly (< 2 seconds eachtime) will increase the Third Digit from 0 to 9 in increments

Strona 127 - REFERENCE

76SERIAL NUMBER (ATOM)• Depressing the A and S buttons simultaneously for 8 secondswhile in the SURFACE MODE will access a SERIAL NUMBERscreen. Infor

Strona 128 - Fig. 117 - ATOM Case Back

77PLAN MODEOceanic strongly recommends that you review the Pre Dive Planning Se-quence (PDPS) prior to every dive to help you plan your dive as requir

Strona 129

78NOTE: When the Conservative Factor is set ON,No Decompression Dive times are reduced to thevalues of the next 3000 foot (915 meter) higherAltitude.

Strona 130

79PLAN MODE information includes (Fig. 71):> Alpha graphic PLAN.> Maximum Depth allowed and symbols MAX and FT (or M), ifset for a Nitrox dive

Strona 131

8FCC ID: MH8AFCC COMPLIANCE:This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following twoconditions: 1.) this equ

Strona 132

80FLY MODE information includes (Fig. 72):> Alpha graphic FLY and symbol TIME.> Countdown Time (hours:minutes).> Battery icon (if a Low Ba

Strona 133

81> The SAT screen is not displayed after a Violation Dive.> Desaturation requiring Times greater than 24 hours shall display 23: - - .> I

Strona 134

82DIVE LOG MODELOG MODE displays information from the latest 24 dives sequentially in reverse order (themost recent first). LOG information is retain

Strona 135

83• Pressing and releasing the S button momentarily (< 2 sec-onds) while viewing a PREVIEW screen will display thatdive’s second LOG screen (Nitro

Strona 136

84LOG NITROGEN DATA information includes (Fig. 75):> Alpha graphic NO-D, DECO, GAUG, or VIOL.> TLBG with the maximum accumulation segment flas

Strona 137 - Transmitter into Regulator

85HISTORY MODEHISTORY Mode displays accumulative information for up to 9999 Dives, 9999 Dive Hours,and the Maximum Depth achieved. HISTORY informatio

Strona 138

86OVERVIEW OF DISPLAYED SYMBOLS AND ICONSSYMBOLS MEANINGMAX FT M Maximum Depth (Feet or Meters)FT M STOP TIME Stop Depth (Feet or Meters) and Ti

Strona 139

87OVERVIEW OF DIVE MODEINFORMATIONWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Refere

Strona 140

88Fig. 78 - Transmitter Signal Reception GuideBestReceptionAreaPoorReceptionAreaPoorReceptionAreaPoorReceptionAreaPoorReceptionAreaPoorReceptionDistan

Strona 141 - SPECIFICATIONS

89POSITIONING OF THE ATOMThe Transmitters emit low frequency signals that radiate outward in semicircular patternsthat are parallel to the length dime

Strona 142

9WARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc. No. 12-2262, whic

Strona 143 - SPECIFICATIONS (CONTINUED)

90An interruption of the Link may also occur while the ATOM is in an area within 3 to 4 feet(1 meter) of a running Dive Propulsion Vehicle. The Link

Strona 144

91against a maximum allowable Nitrogen level. Whichever one isclosest to this maximum level is the controlling compartment forthat Depth. Its result

Strona 145

92When the amount of time remaining before reaching the OxygenLimit becomes less than the No Decompression Dive Time Re-maining, calculations for that

Strona 146

93Air Time Remaining AlarmWhen Air Time Remaining (ATR) decreases to 5 minutes, theAudible Alarm will sound and the LED will flash.If Air Time Remaini

Strona 147

94VARIABLE ASCENT RATEAlerts associated with Ascent Rate are based upon 2 sets ofspeeds which change at a reference depth of 60 feet (18 meters).WARNI

Strona 148 - (from NOAA Diving Manual)

95Ascent Rate Alarm (Fig. 84)At depths deeper than 60 feet (18 meters), an Alarm will soundwhen Ascent Rates exceed 60 feet per minute (20 meters per

Strona 149

96CONTROL OF DISPLAYSDuring Dive Modes, there is a Main (Default) Display of important information relevant tothe specific mode that the ATOM is opera

Strona 150 - INSPECTION / SERVICE RECORD

97DIVE MODESWARNING: Prior to diving with the ATOM, youmust also read and understand the OceanicDive Computer Safety and Reference Manual,Doc. No. 12

Strona 151 - OCEANIC WORLD WIDE

98NO DECOMPRESSION DIVE MODEWhen the Wet Activation feature is set On, the ATOM will enterthe No Decompression Dive Mode any time you descend deeperth

Strona 152

99No Deco Alternate Display #1Information includes (Fig. 86) -• If the Reciver is set OFF, this display will be bypassed.> Tissue Loading Bar Grap

Komentarze do niniejszej Instrukcji

Brak uwag